Description:

CRM pro qualitate et calibratione instrumentorum analyticorum in analysi ferrei Aes, adhibita est, adhibita etiam ad aestimationem et verificationem accurationis methodorum analyticorum.CRM adhiberi potest ad valorem mensurae transferendum.


Product Detail

Product Tags

Product introduction

Coke (2)
Coke (1)

Certified Pretio

Mensa 1. Valores certificati pro GSB 03-2022-2006 (Missa Fractio %)

Numerus

Elementa

TFe

FeO

SiO'2

Al2O3

CaO'

MgO

S

GSB

03-2022-2006

Certified Pretio

61.53

0.24

3.43

2.12

0.118

0.109

0.038

Incerta

0.10

0.01

0.04

0.05

0.007

0.005

0.002

Numerus

Elementa

P

Mn

Ti

K2O

Na2O

Cu

Ni

GSB

03-2022-2006

Certified Pretio

0.093

0.276

0.093

0.024

0.034

0.0014

0.0027

Incerta

0.002

0.005

0.002

0.003

0.003

0.0009

0.0003.

Numerus

Elementa

Co

As

Pb

Zn

Cr

 

 

GSB

03-2022-2006

Certified Pretio

0.0009

0.0011

0.0008

0.0020

0.0078

 

 

Incerta

0.0001

0.0009

0.0001

0.0003

0.0004

 

 

Analysis Methodi

Table 2. Analysis Methodi

Compositio

Methodus

TFe

Methodus titrimetrica post plumbi (Ⅱ) reductionis chloridi

Titanium () chloridum potassium dichromatis methodum titrationes reducendi

FeO

Potassium dichromate titratione methodi

Acidum sulfosalicylicum methodum spectrophotometricam

Potentiometrica methodus titrationis

SiO'2

Acidum perchloricum siccitatis gravimetric

De hyacintho spectrophotometrica methodo silicomolybdica

ICP-AES

CaO'

ASS

ICP-AES

MgO

ASS

ICP-AES

Al2O3

EDTA methodus titrimetrica

ICP-AES

Ti

ICP-AES

Diantipyrylmethane spectrophotometrica methodus

Mn

ICP-AES

ASS

Potassium periodatum spectrophotometricum methodum

P

N-butyl alcohol-chloroform extractionis molybdaeni spectrophotomi caerulei-tritici methodi

The butyl acetate extractionis photometric methodo

Phosphovanoclonoiybeate effusio hypothetica spectromrtric methodo

Bismuth phosphomolybdenum caeruleum photometry

ICP-AES

S

Alta frequentia methodus combustionis ultrarubri effusio

Barium sulfate methodus gravimetrica

Combustio methodi iodometrica

K2O

ICP-AES

ASS

Na2O

ICP-AES

ASS

Cu

ICP-AES

ASS

GFAAS

Ni

ASS

GFAAS

ICP-AES

Co

ASS

GFAAS

ICP-AES

As

Argentum diethyldithiocarbamatum spectrophotometry

Arseno molybdeno methodus spectrophotometrica caerulea post separationem extractionem

GFAAS

HGAAS

ICP-AES

Pb

GFAAS

ASS

ICP-AES

ICP-MS

Zn

ICP-AES

ASS

Cr

ASS

GFAAS

ICP-AES

Stipare et at

Materia relativa certificata referta est in utribus vitreis cum operculis plasticis.Rete pondus 50g unumquodque.Propositum est conservare siccitatem conditam.Materia relativa certificata ante usum 105℃ per 1 horae exsiccari debet, deinde eximenda et refrigerata ad gazophylacium temperatura.

Laboratorium

Name: Shandong Institutum Scientiae Metallurgicae Co., Ltd.

Oratio : 66 Jiefang East Road, Jinan, Shandong, China;

Website:www.cncrms.com

Emai:cassyb@126.com

New standard coal1

Probatus a: Gao Hongji

Laboratorium Director

Data: Die 1 Februarii, 2013


  • Previous: